Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 52-57, 2002.
Article in English | WPRIM | ID: wpr-329132

ABSTRACT

To evaluate the possibility and accuracy of Doppler tissue image (DTI) on assessment of normal and abnormal ventricular activation and contraction sequence, 9 open chest canine hearts were analyzed by acceleration mode, M-mode, and spectrum mode DTI. Our results showed that: (1) Acceleration mode DTI could show the origin of activation and conduction sequence on line; (2) M-mode DTI revealed that the activation in mid-interventricular septum was earlier than that in mid-left ventricular posterior wall at sinus activation; (3) Spectrum DTI showed the ventricular endocardium was activated earlier than the ventricular epicardium in all segments at sinus rhythm. The earliest site of activation of the normal ventricular wall was at middle interventricular septum; the latest site was at basal-posterior wall; the contraction sequence was different at the different walls; (4) During abnormal ventricular activation, mid-left ventricular posterior wall was activated earliest in accordance with the pacing sites. Abnormal ventricular activation was slower than sinus activation, and the contraction sequence varied at different sites of ventricular wall. It is concluded that DTI can be used to localize the origin of normal or abnormal myocardial activation and to assess the contraction sequence conveniently, accurately and non-invasively.


Subject(s)
Animals , Dogs , Echocardiography, Doppler , Methods , Heart Ventricles , Diagnostic Imaging , Myocardial Contraction , Physiology , Sinoatrial Node , Physiology , Tachycardia , Diagnostic Imaging
2.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 52-7, 2002.
Article in English | WPRIM | ID: wpr-634056

ABSTRACT

To evaluate the possibility and accuracy of Doppler tissue image (DTI) on assessment of normal and abnormal ventricular activation and contraction sequence, 9 open chest canine hearts were analyzed by acceleration mode, M-mode, and spectrum mode DTI. Our results showed that: (1) Acceleration mode DTI could show the origin of activation and conduction sequence on line; (2) M-mode DTI revealed that the activation in mid-interventricular septum was earlier than that in mid-left ventricular posterior wall at sinus activation; (3) Spectrum DTI showed the ventricular endocardium was activated earlier than the ventricular epicardium in all segments at sinus rhythm. The earliest site of activation of the normal ventricular wall was at middle interventricular septum; the latest site was at basal-posterior wall; the contraction sequence was different at the different walls; (4) During abnormal ventricular activation, mid-left ventricular posterior wall was activated earliest in accordance with the pacing sites. Abnormal ventricular activation was slower than sinus activation, and the contraction sequence varied at different sites of ventricular wall. It is concluded that DTI can be used to localize the origin of normal or abnormal myocardial activation and to assess the contraction sequence conveniently, accurately and non-invasively.


Subject(s)
Echocardiography, Doppler/instrumentation , Echocardiography, Doppler/methods , Heart Ventricles/diagnostic imaging , Myocardial Contraction/physiology , Sinoatrial Node/physiology , Tachycardia/physiopathology , Tachycardia/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL